WIRING OVERVIEW
Electrical connections are made via pluggable terminal blocks located inside
the meter. All conductors should conform to the meter's voltage and current
ratings. All cabling should conform to appropriate standards of good installation,
local codes and regulations. It is recommended that the power supplied to the
meter (DC or AC) be protected by a fuse or circuit breaker. When wiring the
TBA
TBC
Front
meter, compare the numbers on the label on the back of the meter case against
those shown in wiring drawings for proper wire position. Strip the wire, leaving
approximately 0.4" (10 mm) bare lead exposed (stranded wires should be tinned
with solder.) Insert the lead under the correct screw clamp terminal and tighten
until the wire is secure. (Pull wire to verify tightness.) Each terminal can accept
up to one #14 AWG (2.55 mm) wire, two #18 AWG (1.02 mm), or four #20
Front
TBC
TBD
AWG (0.61 mm). Use copper conductors only, with insulation rated at 90°C.
TBB
WIRING CONNECTIONS
Internal removable terminal blocks are used for power and signal wiring.
Access to terminal blocks is through conduit fittings. Remove end plates with
?" nut driver. For LD4 versions, all wiring is on right side of unit. For LD2
1
LD2 Left Side
versions, power and input wiring connections are on the right side and the relay
and serial connections are on the left side.
8
TBA
LD4
TBD
Front
1
8
TBB
LD2 Right Side
3.1 POWER WIRING
The power wiring is made via the 3 position terminal block (TBA) located
inside the unit (right side). The DC out power is located on TBB (right side).
Power
Terminal 1: VAC/DC +
+
1 L1
DC Out Power
Terminal 4: + 24 VDC OUT
4 + EXC
Terminal 2: VAC/DC -
Terminal 3: Protective Conductor
Terminal
-
2 L2
TBA
Terminal 6: User Common
6 COMM
TBB
3
3.2 RESET/USER INPUT WIRING
The Reset/User Input is located on the right side
Terminal 5: Reset/User Input
Sinking Logic
Sourcing Logic
Terminal 6: User Common
5 RESET/USER
6 COMM
TBB
5 RESET/USER
6 COMM
TBB
DIP switch 6 OFF
3.3 SETPOINT (OUTPUT) WIRING
The setpoint relay uses a three position terminal block (TBC) located on the
left side of the LD2 model, and on the right side for the LD4 model.
DIP switch 6 ON
Terminal 1: Normally Closed
Terminal 2: Normally Open
1 NC
Terminal 3: Relay Common
2 NO
TBC
3 COMMON
4
相关PDF资料
LFSTBEB7361 BOARD DEV ACCELEROMETER MMA7361L
LFSTBEB7455 BOARD DEV ACCELEROMETER MMA7455L
LFSTBEB8450 BOARD DEV ACCELEROMETER MMA8450
LFSTBEB845X EVAL BOARD FOR MMA845XQ
LH1518AT RELAY SSR SPST 250V 300MA 6DIP
LI12-1A79 RELAY REED SPST 1A 12V
LK1AF-24V RELAY GEN PURPOSE SPST 5A 24V
LKG1AF-24V-16-1 RELAY GEN PURPOSE SPST 16A 24V
相关代理商/技术参数
LD50 制造商:General Tools 功能描述:Deluxe Lightning Detector 制造商:General Tools 功能描述:DETECTOR LIGHTNING
LD-50 制造商:API TECHNOLOGIES 功能描述: 制造商:API Technologies Corp 功能描述:
LD5000 制造商:WTE 制造商全称:Won-Top Electronics 功能描述:50A 10mm LUCAS TYPE PRESS-FIT DIODE
LD5001 制造商:WTE 制造商全称:Won-Top Electronics 功能描述:50A 10mm LUCAS TYPE PRESS-FIT DIODE
LD5002 制造商:WTE 制造商全称:Won-Top Electronics 功能描述:50A 10mm LUCAS TYPE PRESS-FIT DIODE
LD5003 制造商:WTE 制造商全称:Won-Top Electronics 功能描述:50A 10mm LUCAS TYPE PRESS-FIT DIODE
LD5004 制造商:WTE 制造商全称:Won-Top Electronics 功能描述:50A 10mm LUCAS TYPE PRESS-FIT DIODE
LD5005 制造商:WTE 制造商全称:Won-Top Electronics 功能描述:50A 10mm LUCAS TYPE PRESS-FIT DIODE